Enviro-Line Walk-In Environmental Chambers

Walk-in environmental chambers, built to your spec

A Norlake walk-in environmental chamber controls temperature, humidity, and light at room scale, with the geometry, refrigeration, monitoring, and installation engineered around your application.

Norlake Scientific Enviro-Line customized environmental room with white exterior
±0.15°C controlAir or water-cooledIndoor / outdoor
+40 to -30°C
Temperature range
to 95% RH
Humidity & light control
Air / water
Cooled refrigeration
4" modular
Cam-lock panel construction
Laboratory technician working beside controlled environmental equipment

Room conditions, controls, and construction are confirmed during engineering review.

Engineer the walk-in chamber around the operating profile

Conditions, room load, access, geometry, monitoring, and facility constraints determine the chamber configuration.

Temperature

+40 to -30°C

Define the operating range and whether the room will run constant or changing setpoints.

Humidity

To 95% RH

Match humidification capacity and control accuracy to the application.

Footprint

Custom size

Configure the room around available space, workflow, and sample volume.

Refrigeration

Air / water

Select air- or water-cooled refrigeration and optional redundancy.

Monitoring

Optional LogiTemp Plus

Plan optional programmable controls, alarm packages, chart recording, and remote visibility.

Choose the format that fits the work

Both formats are modular, walk-in systems. The right starting point depends on the room geometry, control profile, and study workflow you need to support.

Enviro-Line environmental room

A customized modular room configured around your footprint and controlled-environment requirements.

Best when room size, shape, placement, or operating conditions need to be engineered to the project.

  • Multi-temperature or constant-temperature operation
  • Indoor or outdoor configurations
  • Air- or water-cooled refrigeration
  • Optional redundant refrigeration
View platform details

Environmental test chamber

A modular walk-in chamber for programmable temperature and humidity simulation.

Best when a study requires product stress or stability testing in a dedicated controlled chamber.

  • Programmable temperature and humidity
  • Walk-in modular construction
  • Chart recording and alarm options
  • Redundant refrigeration available
Explore stability chambers

The room performs as one engineered system

Refrigeration, controls, humidity, lighting, and panels configured together

Capsule Pak refrigeration

Industrial-quality air- or water-cooled systems are custom-designed to match the room, with optional redundant refrigeration for failure protection.

Redundant option

Optional LogiTemp Plus controls

Available programmable controls can support temperature, humidity, and lighting, with optional remote tablet monitoring and chart-recorder documentation.

±0.15°C / ±1.0% RH

Humidity and UV options

Ultrasonic humidification supports demanding humidity requirements, with UV disinfection systems available for the room configuration.

Up to 8 lb water/hr

Specify the room with confidence

A custom room becomes easier to specify when the environmental target, facility constraints, and monitoring needs are defined early.

Define the conditions

Share the required temperature, humidity, lighting, sample volume, and operating profile.

Configure the system

Engineering aligns the room geometry, panels, refrigeration, controls, and monitoring to the application.

Plan the installation

Indoor or outdoor placement, utilities, access, and optional redundancy are confirmed for the project.

Document performance

Optional programmable controls, alarm packages, remote monitoring, and chart recording can support ongoing visibility.

Built for the people who install and depend on it

More than 25 years of field experience with Norlake Scientific rooms

Life Sciences Review — Top Clinical Lab Equipment Company award for Norlake
I have been installing Norlake Scientific rooms for well over 25 years. Their engineering support, overall design of refrigeration equipment, controls, and flexible panel configuration makes installations go smoothly on the job site. As a field technician, I feel Norlake is on the leading edge of refrigeration design and controls.
Jimmy KeenanPresident, JK Services

Backed beyond installation

Enviro-Line rooms combine long-term warranty coverage with recognized product listings. Confirm project-specific requirements during engineering review.

15 yr

Panel warranty

5 yr

Compressor warranty

  • UL listed
  • C-UL listed
  • NSF listed
  • USDA accepted
  • CEC
  • California State
  • City of LA / Houston
  • Oregon State

Environmental room FAQ

Direct answers to the configuration, controls, installation, and monitoring questions teams ask before engineering review.

What is a walk-in environmental chamber?
A walk-in environmental chamber is a room-scale controlled environment used to reproduce and monitor specified temperature, humidity, and lighting conditions around people, samples, carts, shelving, and study workflows.
What conditions can an Enviro-Line room maintain?
Enviro-Line rooms can be configured across a +40°C to -30°C temperature range, with humidification up to 95% RH and programmable lighting. Final operating envelopes are confirmed during engineering review for the specific application.
How precise is temperature and humidity control?
Advanced Enviro-Line controls regulate to ±0.15°C and ±1.0% RH. Environmental test chamber configurations are listed at ±0.5°C and ±5.0% RH.
Can the room run constant or changing temperature conditions?
Yes. Customized environmental rooms can be configured for constant-temperature or multi-temperature operation, depending on the study and control profile.
Should refrigeration be air-cooled or water-cooled?
Enviro-Line rooms can use air- or water-cooled Capsule Pak refrigeration. The appropriate configuration depends on the facility, utilities, room load, and installation conditions and is selected during engineering review.
Is redundant refrigeration available?
Yes. An optional redundant refrigeration system can be configured for applications that require additional failure protection.
Can an environmental room be installed indoors or outdoors?
Yes. Enviro-Line rooms are available in indoor and outdoor configurations. Placement, utilities, access, and site conditions are reviewed as part of project engineering.
How are room conditions monitored and documented?
Optional LogiTemp Plus controls can provide programmable temperature, humidity, and lighting control. Remote tablet monitoring, chart recorders, and high/low or power-failure alarms are available based on the selected configuration.
What information is needed to request a quote?
Start with the required temperature and humidity range, lighting needs, application, room footprint, installation location, sample volume, and monitoring requirements. Norlake engineers use those inputs to configure the room.

Bring us the conditions. We'll engineer the room.

Share your temperature, humidity, lighting, footprint, and monitoring requirements to start an Enviro-Line configuration.