Products · Custom temperature & humidity chambers

Build the chamber around the test

Enviro-Line walk-in chambers reproduce and monitor specified combinations of temperature, humidity, and light through custom room geometry, refrigeration, controls, finishes, monitoring, and optional redundancy.

Norlake Scientific Enviro-Line custom temperature and humidity chamber
Custom geometryPublished advanced control accuracyAir or water cooled
±0.15°C
Published control accuracy
±1.0% RH
Published control accuracy
Custom
Size, shape, and finish
Optional
Redundant refrigeration
Custom walk-in environmental chamber with programmable control panel

Room conditions, controls, and construction are confirmed during engineering review.

Define the operating envelope before the hardware

A chamber specification should describe the environment, loads, geometry, facility, controls, monitoring, and consequences of an excursion.

Environment

Operating envelope

Define temperature, humidity, lighting, transitions, and operating schedule.

Load

Calculated

Document materials, heat and moisture loads, racks, carts, and equipment.

Geometry

Custom

Plan size, shape, compartments, doors, windows, floors, and finishes.

Facility

Site fit

Confirm placement, utilities, ambient, and air- or water-cooled refrigeration.

Controls

Configurable

Select optional alarms, chart recorders, building integration, remote access, and redundancy.

The Enviro-Line custom chamber platform

Choose room geometry, construction, refrigeration, humidification, lighting, controls, monitoring, integration, and optional redundancy around the engineering brief.

Turn the test plan into a chamber specification

The final configuration follows the operating envelope, physical loads, facility, and oversight requirements.

Define the envelope

Document conditions, transitions, schedule, and allowable operating limits.

Map loads & geometry

Review materials, equipment, racks, carts, doors, and compartments.

Select the systems

Configure refrigeration, humidity, lighting, controls, finishes, and monitoring.

Confirm the project

Coordinate installation scope, utilities, documentation, and service access.

Proven, leading-edge refrigeration

Recognized by Life Sciences Review · Trusted across labs, research & pharma

Life Sciences Review — Top Clinical Lab Equipment Company award for Norlake
I have been installing Norlake Scientific rooms for well over 25 years. Their engineering support, overall design of refrigeration equipment, controls, and flexible panel configuration makes installations go smoothly on the job site. As a field technician, I feel Norlake is on the leading edge of refrigeration design and controls.
Jimmy KeenanPresident, JK Services

Verified platform proof

Norlake combines modular insulated construction, configurable controls, proven refrigeration components, published warranties, and broad product listings. Application-specific qualification or compliance is defined separately for each project.

15 yr

Panel warranty

40+ yrs

Refrigeration expertise

  • UL listed
  • C-UL listed
  • NSF listed
  • USDA accepted
  • Hi/Lo alarm option
  • Redundant option

Temperature & humidity chamber FAQ

Technical answers for engineers, lab planners, and test teams evaluating a custom walk-in chamber.

What is a temperature and humidity chamber?
It is a controlled enclosure used to create and monitor specified environmental conditions for testing, storage, research, or stability work. Walk-in chambers provide room-scale capacity.
Can the chamber be custom sized?
Yes. Enviro-Line rooms are available in custom sizes, shapes, finishes, and compartment layouts, subject to engineering review and site requirements.
What control accuracy does Norlake publish?
Norlake publishes advanced-control accuracy of ±0.15°C and ±1.0% RH. That is a control-system capability statement, not a blanket claim of room uniformity, mapping, or validated performance.
Can refrigeration be air or water cooled?
Yes. Enviro-Line industrial refrigeration systems may be configured as air- or water-cooled based on the application and facility.
Can the chamber connect to a building system?
Control panels can be configured to integrate with existing building systems. Available monitoring also includes alarms, chart-recording options, and remote access.
Is redundant refrigeration available?
Yes. Optional redundant refrigeration can be specified when the consequence of a system interruption justifies it.
What should I send for a quote?
Provide the operating range, humidity, lighting, loads, room dimensions, installation location, utilities, doors, finishes, controls, monitoring, documentation, and redundancy requirements.

Custom chamber resources

Review the Enviro-Line platform and start the quote with the operating envelope, loads, facility, and monitoring requirements.

Bring the operating envelope

Share temperature, humidity, lighting, transitions, loads, geometry, utilities, controls, monitoring, and installation requirements.